Cisco Wsc296024tcl Catalyst 2960 24port 10100 Managed Switch Business Reviews
The Cisco ® Catalyst ® 2960-S and 2960 Serial Switches are the leading Layer ii edge switches, providing improved operational excellence, highly secure business operations, improved sustainability, and an enhanced workspace feel. They are fixed-configuration access switches designed for entry-level enterprise, midmarket, and branch office networks. Figure 1 shows the Cisco Goad 2960-S Series Switch model and Figure 2 shows the Cisco Goad 2960 Serial Switch model with LAN Calorie-free software.
The Cisco Catalyst 2960-Due south Series Switches with LAN Calorie-free Software have the following capabilities:
● 24 and 48 ports of Gigabit Ethernet (GbE) ten/100/k desktop connectivity
● 1 GbE Small Grade-Factor Pluggable (SFP) uplinks
● USB storage interface for file fill-in, distribution, and simplified operations
● Enhanced troubleshooting for trouble solving, including link connectivity and cable diagnostics
● Single IP accost management for upwardly to 16 switches
● A wide range of software features to provide ease of operation, secure business operations, sustainability and borderless networking experience
● Limited lifetime hardware warranty, including next-business organisation-day replacement with 90-day service and support
The Cisco Catalyst 2960 Series Switches with LAN Lite Software have the post-obit capabilities:
● Fast Ethernet connectivity with Ability over Ethernet (PoE) of up to 15.4W per port
● GbE for information connectivity
● Enhanced troubleshooting for problem solving, including link connectivity and cable diagnostics
● Single IP address management for up to 16 switches
● A broad range of software features to provide ease of operation, highly secure business operations, sustainability, and a borderless networking experience
● Limited lifetime hardware warranty
Figure one. Cisco Catalyst 2960-S and 2960 Serial Switches with LAN Calorie-free Software
Figure 2. Cisco Catalyst 2960-S Series Switches with LAN Calorie-free Software
Switch Configurations
Table 1 shows the configuration information for the Cisco Catalyst 2960-Due south and 2960 Series Switches with LAN Lite Software.
Table 1. Configurations of Cisco Goad 2960-S and 2960 Series Switches with LAN Calorie-free Software
Switch Model | Description | Uplinks |
Catalyst 2960-S Switches with 1 Gigabit Uplinks and 10/100/1000 Ethernet Connectivity | ||
Cisco Catalyst 2960S-48TS-S | 48 Ethernet 10/100/chiliad | 2 one GbE ports |
Cisco Catalyst 2960S-24TS-S | 24 Ethernet 10/100/1000 | 2 ane GbE SFP ports |
Goad 2960 Switches with 1 Gigabit Uplinks and 10/100 Ethernet Connectivity | ||
Cisco Catalyst 2960-48PST-S | 48 Ethernet x/100 PoE ports (370W capacity) | 2 fixed x/100/1000 ports and 2 SFP ports |
Cisco Catalyst 2960-24PC-Due south | 24 Ethernet ten/100 PoE ports (370W chapters) | ii dual-purpose ports (ten/100/g or SFP) |
Cisco Goad 2960-24LC-Due south | 24 Ethernet ten/100 and eight 10/100 PoE ports (123W capacity) | two dual-purpose ports (10/100/1000 or SFP) |
Cisco Catalyst 2960-48TC-S | 48 Ethernet 10/100 | two dual-purpose ports (x/100/1000 or SFP) |
Cisco Catalyst 2960-48TT-S | 48 Ethernet x/100 | 2 fixed 10/100/1000 ports |
Cisco Catalyst 2960-24TC-S | 24 Ethernet 10/100 | ii dual-purpose ports (ten/100/1000 or SFP) |
Cisco Catalyst 2960-24-Due south | 24 Ethernet 10/100 | None |
Meaty Switches | ||
Cisco Catalyst 2960-8TC-Southward | 8 Ethernet 10/100 meaty size with no fan | 1 dual-purpose port (10/100/one thousand or SFP) |
Cisco Goad 2960-Southward and 2960 Series Switches Enable Cisco Borderless Network
The Cisco Borderless Network Architecture delivers the new workspace experience, connecting anyone, anywhere, using any device, to any resource deeply, reliably, and transparently. The Cisco Borderless Networks architecture addresses master Information technology and business challenges to help create a truly borderless experience by bringing interactions closer to the employee and customer.
Borderless experience is but possible with intelligent network elements designed and architected to see the needs of a global workspace. Cisco Network Access is a chief component of this architecture, enabling various borderless network services such as mobility, security, EnergyWise, and ease of operations for increased productivity and operational efficiency.
Cisco Network Access for Borderless solution focuses on the following primary areas:
● Sustainability
● Ease of operations
● Borderless security
● Borderless experience
Sustainability
Cisco Catalyst switching solutions enable greener practices through measurable power efficiency, integrated services, and continuous innovations such every bit Cisco EnergyWise, an enterprisewide solution that monitors and conserves energy with customized policies. Together, Cisco EnergyWise technology and Cisco Catalyst switches reduce greenhouse gas (GhG) emissions and increase free energy cost savings and sustainable business concern beliefs. Sustainability features in the Cisco Catalyst 2960-S and 2960 Series Switches include the following features sets:
● Cisco EnergyWise technology
● Efficient switch functioning
● Intelligent ability management
Cisco EnergyWise Engineering
Cisco EnergyWise is an innovative architecture, added to stock-still configuration switches, promoting companywide sustainability by reducing energy consumption across an entire corporate infrastructure and affecting more than 50 pct of global greenhouse gas emissions created by worldwide edifice infrastructure, a much greater effect than the 2 percent generated by the It industry. Cisco EnergyWise enables companies to measure the power consumption of network infrastructure and network-fastened devices and manage ability consumption with specific policies, reducing power consumption to realize increased cost savings, potentially affecting any powered device.
EnergyWise encompasses a highly intelligent network-based approach to communicate messages that measure and control free energy between network devices and endpoints. The network discovers Cisco EnergyWise-manageable devices, monitors their ability consumption, and takes activity based on business rules to reduce power consumption. EnergyWise uses a unique domain-naming system to query and summarize information from large sets of devices, making it simpler than traditional network management capabilities. Cisco EnergyWise'due south management interfaces allow facilities and network direction applications to communicate with endpoints and each other using the network as a unifying fabric. The management interface uses standard Simple Network Management Protocol (SNMP) or TCP to integrate Cisco and third-party management systems.
Efficient Switch Operation
Cisco Goad 2960-S and 2960 Series Switches, designed and engineered by Cisco, provide optimum power saving, low power operations for industry best-in-class power direction, and power consumption capabilities. The Catalyst 2960-S ports are capable of reduced power modes so that ports not in use tin move into a lower power utilization state.
Intelligent Power over Ethernet Management
The Cisco Goad 2960 Series PoE models back up the latest PoE devices including Cisco IP phones and Cisco Aironet WLAN access points providing upward to 15.4W of ability per port, equally well as whatever IEEE 802.3af-compliant cease device.
● Per port power consumption command allows customers to specify maximum power setting on an individual port.
● Cisco Discovery Protocol Version 2 allows switches to negotiate a more granular power setting when connecting to a Cisco powered device such equally IP phones or admission points than what is provided by IEEE classification.
● PoE MIB provides proactive visibility into power usage and allows customers to set unlike power-level thresholds.
● IEEE 802.3af and Cisco prestandard PoE back up comes with automatic discovery to detect a Cisco prestandard or IEEE 802.3af endpoint and provide the necessary power without any user configuration. Per-port PoE power sensing measures the actual power beingness drawn, enabling more than intelligent control of powered devices.
Table ii lists the PoE chapters of the Cisco Goad 2960 Series Switches.
Table 2. Switch PoE Power Capacity
Switch Model | Maximum Number of PoE Ports* | Bachelor PoE Power |
Cisco Goad 2960-48PST-S | 24 ports up to 15.4W 48 ports upward to vii.7W | 370W |
Cisco Catalyst 2960-24PC-Southward | 24 ports up to xv.4W | 370W |
Cisco Catalyst 2960-24LC-South | 8 ports up to 15.4W | 123W |
*Intelligent power allows flexible ability allocation across all ports.
Ease of Operations
The Cisco Goad 2960-S and 2960 Serial Switches help reduce the operating costs through:
● Cisco Catalyst Smart Operations
● Easy to use deployment and control features
● Avant-garde, intelligent network management tools
Cisco Catalyst Smart Operations
Cisco Goad Smart Operations is a comprehensive set of capabilities that simplify LAN deployment, configuration, and troubleshooting. Cisco Goad Smart Operations enable goose egg-touch installation and replacement of switches, fast upgrade, as well as ease of troubleshooting with reduced operational cost.
Cisco Catalyst Smart Operations is a set of features that includes Smart Install, Auto Smartports, Smart Configuration, and Smart Troubleshooting to raise operational excellence:
● Cisco Smart Install is a transparent plug-and-play engineering to configure the Cisco IOS Software image and switch configuration without user intervention. Smart Install utilizes dynamic IP address allocation and the assistance of other switches to facilitate installation providing transparent network plug and play.
● Cisco Auto Smartports provide automatic configuration as devices connect to the switch port, allowing automobile detection and plug and play of the device onto the network.
Easy to Apply Deployment and Command Features
● Auto-negotiation on all ports automatically selects one-half- or total-duplex manual mode to optimize bandwidth.
● Dynamic Trunking Protocol (DTP) facilitates dynamic body configuration across all switch ports.
● Port Aggregation Protocol (PAgP) automates the cosmos of Cisco Fast EtherChannel ® groups or Gigabit EtherChannel groups to link to another switch, router, or server.
● Link Aggregation Control Protocol (LACP) allows the creation of Ethernet channeling with devices that conform to IEEE 802.3ad. This characteristic is similar to Cisco EtherChannel engineering science and PAgP.
● Automatic media-dependent interface crossover (MDIX) automatically adjusts transmit and receive pairs if an incorrect cable type (crossover or straight-through) is installed.
● Unidirectional Link Detection Protocol (UDLD) and Aggressive UDLD let unidirectional links caused by incorrect fiber-optic wiring or port faults to be detected and disabled on cobweb-optic interfaces.
● Dynamic Host Configuration Protocol (DHCP) autoconfiguration of multiple switches through a boot server eases switch deployment.
● Switching Database Manager (SDM) templates for access, routing, and VLAN deployment allow the administrator to easily maximize memory allocation to the desired features based on deployment-specific requirements.
● Local Proxy Address Resolution Protocol (ARP) works in conjunction with Private VLAN Edge to minimize broadcasts and maximize available bandwidth.
● Internet Group Management Protocol (IGMP) Snooping for IPv4 and IPv6 MLD v1 and v2 Snooping provide fast client joins and leaves of multicast streams and limit bandwidth-intensive video traffic to only the requestors.
● Per-port broadcast, multicast, and unicast storm command prevents faulty end stations from degrading overall systems performance.
● Voice VLAN simplifies telephony installations by keeping voice traffic on a dissever VLAN for easier administration and troubleshooting.
● Cisco VLAN Trunking Protocol (VTP) supports dynamic VLANs and dynamic trunk configuration across all switches.
● Switch Port Analyzer (Bridge) allows administrators to monitor ports in a Layer 2 switch network from any other switch in the same network.
● For enhanced traffic management, monitoring, and assay, the Embedded Remote Monitoring (RMON) software agent supports four RMON groups (history, statistics, alarms, and events).
● Trivial File Transfer Protocol (TFTP) reduces the cost of administering software upgrades by downloading from a centralized location.
● Network Timing Protocol (NTP) provides an accurate and consistent timestamp to all intranet switches.
● Cisco Emergency Responder (CER) enhances emergency calling from Cisco Unified CallManager. It helps assure that Cisco Unified CallManager sends emergency calls to the appropriate Public Rubber Answering Bespeak (PSAP) for the caller'due south location.
Advanced, Intelligent Network Direction Tools
The Cisco Catalyst 2960-Due south and 2960 Series Switches offer both a superior CLI for detailed configuration and Cisco Network Banana software, a PC-based tool for quick configuration based on preset templates. In improver, CiscoWorks LAN Management Solution (LMS) supports the Cisco Catalyst 2960-S and 2960 Series Switches for networkwide direction.
Cisco Network Assistant
A PC-based network management application designed for small and medium-sized business concern (SMB) networks with up to 250 users, Cisco Network Assistant offers centralized network management and configuration capabilities. Cisco Network Banana uses Cisco Smartports technology to simplify both initial deployment and ongoing maintenance. This awarding likewise features an intuitive GUI where users can hands apply common services beyond Cisco switches, routers, and access points, such as:
● Configuration management
● Troubleshooting advice
● Inventory reports
● Issue notification
● Network security settings
● Password synchronization
● Drag-and-drop Cisco IOS Software upgrades
● Secure wireless
For detailed information about Cisco Network Assistant, visit http://www.cisco.com/go/cna.
CiscoWorks LAN Management Solution
CiscoWorks LAN Management Solution (LMS) is a comprehensive network lifecycle management solution. It provides an extensive library of like shooting fish in a barrel-to-use features to automate the initial and day-to-day management of your Cisco network infrastructure. CiscoWorks LMS uniquely uses Cisco hardware and software platform knowledge and operational feel into a powerful gear up of workflow driven configuration, monitoring, troubleshooting, reporting, and administrative tools. Including:
● Support for new Cisco hardware platforms the twenty-four hours they transport
● Support for new technologies and services from initial deployment to day-to-day administration and direction, such as EnergyWise, Identity, Cisco Auto Smartports, Cisco Smart Install, and much more
● Configuration management tools built from Cisco experience and Cisco Validated Blueprint recommendations
● Monitoring and troubleshooting capabilities that incorporates Cisco hardware all-time practices and diagnostics features
● Automation in managing hardware inventories, security vulnerabilities (PSIRTS) and platform end-of-life and support cycles
For detailed data about CiscoWorks LMS, go to: http://www.cisco.com/en/US/products/sw/cscowork/ps2425/index.html.
Borderless Security
The Cisco Catalyst 2960-Due south and 2960 LAN Calorie-free Series Switches provide basic TrustSec, a primary element of Borderless Security Architecture, that helps enterprise customers secure their networks, information and resource with policy-based access control, identity-aware and office-enlightened networking, pervasive integrity, and confidentiality. The borderless security is enabled past the post-obit feature sets in the Cisco Goad 2960-S and 2960 Serial Switches:
● Basic Cisco TrustSec
● Other security features
Cisco TrustSec
● The Cisco TrustSec solution provides hallmark, access control, and security policy administration to secure network connectivity and resources. On the Cisco Catalyst 2960-S and 2960 Series with LAN Lite, the TrustSec solution prevents unauthorized admission and helps ensure that users get only their designated privileges. It provides the power to dynamically administer granular levels of network admission.
Other Security Features
Other Advanced Security features include simply are not express to:
● MAC Auth Featherbed (MAB) for vocalisation allows third-party IP phones without an 802.1X supplicant to get authenticated using their MAC accost.
● Port security can be used to limit access on an Ethernet port based on the MAC address of the device to which it is connected. Information technology also can be used to limit the total number of devices plugged into a switch port, thereby protecting the switch from a MAC flooding assail as well as reducing the risks posed by rogue wireless access points or hubs.
● The MAC Address Notification feature tin can exist used to monitor the network and track users past sending an warning to a management station so that network administrators know when and where users enter the network.
● Secure Shell (SSH) Protocol v2 and Elementary Network Management Protocol (SNMP) v3 provide network security by encrypting ambassador traffic during Telnet and SNMP sessions. SSH v2 and the cryptographic version of SNMP v3 require a special cryptographic software image considering of U.S. export restrictions.
Borderless Experience
Borderless network enables enterprise mobility and business-grade video services. Industry'south offset unified network (wired and wireless) location services enable tracking of mobile assets and the users of those assets for both wired and wireless devices. The true borderless feel is enabled by the following characteristic sets in the Cisco Catalyst 2960-S and 2960 Series Switches:
● Layer 2 Networking
● QoS
Layer 2 Networking
The Cisco 2960-South and 2960 Series Switches provide Layer 2 networking to enable availability.
Features include but are non limited to:
● IEEE 802.1s/w Rapid Spanning Tree Protocol (RSTP) and Multiple Spanning Tree Protocol (MSTP) provide rapid spanning-tree convergence independent of spanning-tree timers and also offers the benefit of Layer 2 load balancing and distributed processing.
● Per-VLAN Rapid Spanning Tree (PVRST+) allows rapid spanning-tree reconvergence on a per-VLAN spanning-tree footing, without requiring the implementation of spanning-tree instances.
● Switch-port autorecovery (Errdisable) automatically attempts to reactivate a link that is disabled because of a network error.
● Up to 64 VLANs and up to 64 spanning-tree instances per switch are supported.
Quality of Service
The Cisco Catalyst 2960-Due south and 2960 Serial Switches offers intelligent services that go along everything flowing smoothly. Industry-leading mechanisms for mark, classification, and scheduling evangelize superior operation for data, vocalism, and video traffic, all at wire speed.
Post-obit are some of the QoS features supported in the Cisco 2960-S and 2960 Series Switches:
● 802.1p class of service (CoS) classification provides differentiated services when all-time-effort traffic delivery is bereft.
● Four egress queues per port help enable differentiated direction of different traffic types beyond the stack.
● Shaped Round Robin (SRR) scheduling helps ensure differential prioritization of packet flows by intelligently servicing the ingress queues and egress queues.
● Weighted Tail Drib (WTD) provides congestion avoidance at the ingress and egress queues before a disruption occurs.
Tables 3, 4, 5, 6 and 7 provide hardware features, power specifications, management and standards, and safety and compliance information for the Cisco Catalyst 2960-S and 2960 Series Switches with LAN Light Software.
Table 3. Hardware Features for Cisco Catalyst 2960-S and 2960 Series Switches with LAN Lite Software
Performance and Scalability Numbers for All Switch Models | |||||||||
Forwarding bandwidth | 16 Gbps (2960), l Gbps (2960-Due south) | ||||||||
Wink memory | 32 MB (2960), 64 MB (2960-S) | ||||||||
Retentiveness DRAM | 64 MB (2960), 128 MB (2960-S) | ||||||||
Max VLANs | 64 | ||||||||
VLAN IDs | 4000 | ||||||||
Maximum transmission unit (MTU) | Upwards to 9198 bytes | ||||||||
Jumbo frames | 9016 bytes (2960), 9216 bytes (2960-S) | ||||||||
Forwarding Rate | |||||||||
2960S-48TS-Due south | 74.four mpps | ||||||||
2960S-24TS-S | 38.7 mpps | ||||||||
2960-8TC-Southward | ii.7 mpps | ||||||||
2960-24-South | three.half-dozen mpps | ||||||||
2960-24TC-S | 6.5 mpps | ||||||||
2960-24PC-Due south | 6.v mpps | ||||||||
2960-24LC-S | 6.v mpps | ||||||||
2960-48TT-S | x.ane mpps | ||||||||
2960-48TC-S | 10.1 mpps | ||||||||
2960-48PST-S | 13.3 mpps | ||||||||
Resources | Default | QoS | Dual | ||||||
Unicast MAC addresses | 8000 | 8000 | 8000 | ||||||
IPv4 IGMP groups | 256 | 256 | 256 | ||||||
IPv4 MAC QoS access control entries (ACEs) | 128 | 384 | 0 | ||||||
IPv4 MAC security ACEs | 384 | 128 | 256 | ||||||
Connectors and Cabling and Indicators | |||||||||
● 10BASE-T ports: RJ-45 connectors, 2-pair Category 3, iv, or 5 unshielded twisted-pair (UTP) cabling ● 100BASE-TX ports: RJ-45 connectors, 2-pair Category v UTP cabling ● 1000BASE-T ports: RJ-45 connectors, four-pair Category 5 UTP cabling ● 1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling ● 1000BASE-SX, -LX/LH SFP-based ports: LC fiber connectors (single- and multimode fiber) ● 100Base-FX: LC fiber connectors (single- and multimode cobweb) | |||||||||
● Customers tin can provide power to a switch only by using the internal power supply. The connector is located at the back of the switch. These switches do not have a redundant-power-supply port. ● The internal power supply is an machine-ranging unit. ● The internal power supply supports input voltages betwixt 100 and 240 VAC. ● Utilize the supplied AC power cord to connect the Ac ability connector to an Ac ability outlet. | |||||||||
● Per-port status: Link integrity, disabled, action, speed, and full duplex ● System status: Organization, link status, link duplex, PoE, and link speed | |||||||||
● Per-port condition: Link integrity, disabled, action, speed, and full duplex ● Arrangement status: System, link status, link duplex, PoE, and link speed | |||||||||
Dimensions (H x W x D) | |||||||||
Model | Inches | Centimeters | |||||||
2960S-48TS-Southward | 1.75 x 17.7 x 11.8 | 4.5 x 45 x 30 | |||||||
2960S-24TS-S | one.75 x 17.seven x xi.8 | four.5 10 45 x 30 | |||||||
2960-8TC-South | 1.73 x ten.half dozen 10 6.4 | 4.iv x 27 x 16.3 | |||||||
2960-24-S | one.73 ten 17.7 10 nine.52 | iv.four x 45 x 24.2 | |||||||
2960-24TC-S | 1.73 x 17.7 ten ix.52 | four.iv x 45 x 24.2 | |||||||
2960-24PC-S | ane.73 x 17.7 x 13 | 4.4 x 45 x 33.02 | |||||||
2960-24LC-Southward | 1.73 x 17.vii x 13 | 4.4 x 45 x 33.02 | |||||||
2960-48TT-Due south | 1.73 x 17.7 x 9.52 | four.4 x 45 x 24.2 | |||||||
2960-48TC-S | i.73 x 17.vii x nine.52 | iv.4 x 45 x 24.2 | |||||||
2960-48PST-Due south | 1.73 x 17.7 x thirteen | four.iv x 45 x 33.02 | |||||||
Weight | |||||||||
Model | Pounds | Kilograms | |||||||
2960S-48TS-S | 10.5 | 4.8 | |||||||
2960S-24TS-S | 10 | iv.v | |||||||
2960-8TC-Due south | 3 | i.4 | |||||||
2960-24-Due south | 8 | 3.6 | |||||||
2960-24TC-South | eight | 3.6 | |||||||
2960-24PC-S | 12 | v.iv | |||||||
2960-24LC-Southward | 10 | 4.5 | |||||||
2960-48TT-Due south | 8 | 3.6 | |||||||
2960-48TC-Due south | 8 | 3.vi | |||||||
2960-48PST-S | 12 | 5.four | |||||||
Environmental ranges | |||||||||
Fahrenheit | Centigrade | ||||||||
Operating temperature up to 5000 ft (1500 m) | 23º to 113ºF | -5º to 45ºC | |||||||
Operating temperature up to 10,000 ft (3000 m) | 23º to 104ºF | -5º to 40ºC | |||||||
Short-term exception at sea level* | 23º to 31ºF | -5º to +55ºC | |||||||
Brusk-term exception up to 5,000 anxiety (1500 one thousand)* | 23º to 122ºF | -5º to +50ºC | |||||||
Short-term exception up to ten,000 feet (3000 g)* | 23º to 113ºF | -5º to +45ºC | |||||||
Storage temperature | Same equally above | Same as above | |||||||
Feet | Meters | ||||||||
Operating altitude | Up to 10,000 | Up to 3000 | |||||||
Storage altitude | Up to 13,000 | Up to 4000 | |||||||
Operating relative humidity | 10% to 95% noncondensing | ||||||||
Storage relative humidity | ten% to 95% noncondensing | ||||||||
Audio-visual racket | |||||||||
Measured per ISO 7779 and declared per ISO 9296. Bystander positions operating mode at 25°C ambient. | |||||||||
Sound Pressure | Sound Power | ||||||||
Model | LpA (Typical*) | LpAD (Maximum*) | LwA (Typical) | LwAD (Maximum) | |||||
2960S-48TS-Southward | 44 dB | 47 dB | 5.4 B | 5.7 B | |||||
2960S-24TS-Due south | |||||||||
2960-24-S | 40 dB | - | - | - | |||||
2960-24TC-S | twoscore dB | - | - | - | |||||
2960-24PC-South | 48 dB | - | - | - | |||||
2960-24LC-South | 48 dB | - | - | - | |||||
2960-48TT-Due south | 40 dB | - | - | - | |||||
2960-48TC-S | forty dB | - | - | - | |||||
2960-48PST-S | 48 dB | - | - | - | |||||
*Typical: Noise emission for a typical configuration and PoE load up to 185W *Maximum: Statistical maximum to account for production variations | |||||||||
Mean time between failures (MTBF) | |||||||||
2960S-48TS-S | 357,740 hours | ||||||||
2960S-24TS-Southward | 335,014 hours | ||||||||
2960-8TC-South | 615,549 hours | ||||||||
2960-24-S | 429,847 hours | ||||||||
2960-24TC-S | 403,745 hours | ||||||||
2960-24PC-S | 242,818 hours | ||||||||
2960-24LC-S | 311,007 hours | ||||||||
2960-48TT-Due south | 339,743 hours | ||||||||
2960-48TC-S | 336,983 hours | ||||||||
2960-48PST-S | 181,979 hours | ||||||||
*Not more than the following in a 1-yr period. 96 sequent hours, or 360 hours total, or xv occurences. Notation: Compact switch 2960-8TC-S (no fan) has 0 dB sound pressure. | |||||||||
Tabular array 4. Power Specifications for Cisco Catalyst 2960-S and 2960 Serial Switches with LAN Lite Software
Description | C2960-S and C2960 Specifications | ||||
Models | C2960S-48TS-S | C2960S-24TS-Southward | C2960-8TC-S | C2960-24TC-S | C2960-24PC-Southward |
100 Per centum Throughput | |||||
Measured Ability Consumption | 53W | 36W | 12W | 22W | 27W |
5 Percent Throughput | |||||
Measured Power Consumption | 50W | 36W | 11W | 21W | 24W |
v Pct Throughput (with fifty Percent PoE Loads) | |||||
Measured Power Consumption | - | - | - | - | Switch Power: 237W PoE Power: 185W |
100 Percent Throughput (with Maximum Possible PoE Loads) | |||||
Measured Power Consumption | - | - | - | - | Switch Ability: 433W PoE Power: 357W |
Description | C2960 Specifications | |||
Models | C2960-24LC-Due south | C2960-48TT-S | C2960-48TC-S | C2960-48PST-South |
100 Percent Throughput | ||||
Measured Power Consumption | 79W | 71W | 55W | 52W |
5 Percentage Throughput | ||||
Measured Ability Consumption | 78W | 70W | 54W | 50W |
5 Percent Throughput (with 50 Percentage PoE Loads) | ||||
Measured Power Consumption | Switch Ability: 98W PoE Ability: 62W | - | - | Switch Power: 460W PoE Power: 339W |
100 Pct Throughput (with Maximum Possible PoE Loads) | ||||
Measured Ability Consumption | Switch Power: 162W PoE Ability: 119W | - | - | Switch Power: 262W PoE Power: 187W |
Table 5. Voltage and Ability Rating for Cisco Catalyst 2960-S and 2960 Series Switches with LAN Light Software
Voltages and Power Rating | |||
Model | Voltage (Autoranging) | Current | Frequency |
2960S-48TS-S | 100 to 240 VAC | 1 to 0.five A | 50 to 60 Hz |
2960S-24TS-S | 100 to 240 VAC | ane to 0.5 A | l to sixty Hz |
2960-8TC-Southward | 100 to 240 VAC | 0.5 to 0.three A | 50 to 60 Hz |
2960-24-Due south | 100 to 240 VAC | 1.three to 0.8 A | 50 to 60 Hz |
2960-24TC-S | 100 to 240 VAC | 1.iii to 0.viii A | 50 to 60 Hz |
2960-24PC-Southward | 100 to 240 VAC | 8.0 to 4.0 A | 50 to 60 Hz |
2960-24LC-S | 100 to 240 VAC | iii.0 to 1.five A | l to 60 Hz |
2960-48TT-S | 100 to 240 VAC | one.iii to 0.8A | 50 to 60 Hz |
2960-48TC-S | 100 to 240 VAC | 1.3 to 0.8A | l to 60 Hz |
2960-48PST-S | 100 to 240 VAC | five.0 to 2.0 A | 50 to 60 Hz |
Model | Ability Rating | ||
2960S-48TS-S | 0.thirteen kVA | ||
2960S-24TS-S | 0.08 kVA | ||
2960-8TC-S | 0.035 kVA | ||
2960-24-Due south | 0.05 kVA | ||
2960-24TC-S | 0.05 kVA | ||
2960-24PC-S | 0.47 kVA | ||
2960-24LC-S | 0.175 kVA | ||
2960-48TT-South | 0.075 kVA | ||
2960-48TC-S | 0.075 kVA | ||
2960-48PST-S | 0.v kVA | ||
● Maximum power supplied per port for PoE is fifteen.4W ● Full power dedicated to PoE is 370W |
Tabular array 6. Direction and Standards Support for Cisco Goad 2960-S and 2960 Series Switches with LAN Lite Software
Description | Specification | |
Management | ● BRIDGE-MIB ● CISCO-CABLE-DIAG-MIB ● CISCO-CDP-MIB ● CISCO-CLUSTER-MI ● CISCO-CONFIG-COPY-MIB ● CISCO-CONFIG-MAN-MIB ● CISCO-ENTITY-VENDORTYPE-OID-MIB ● CISCO-ENVMON-MIB ● CISCO-ERR-DISABLE-MIB ● CISCO-FLASH-MIB ● CISCO-FTP-CLIENT-MIB ● CISCO-IGMP-FILTER-MIB ● CISCO-Epitome-MIB ● CISCO-IP-STAT-MIB ● CISCO-LAG-MIB ● CISCO-MAC-NOTIFICATION-MIB ● CISCO-MEMORY-Pool-MIB ● CISCO-PAGP-MIB ● CISCO-PING-MIB ● CISCO-PORT-QOS-MIB ● CISCO-PORT-SECURITY-MIB ● CISCO-PORT-STORM-CONTROL-MIB ● CISCO-Power-ETHERNET-EXT-MIB ● CISCO-PRODUCTS-MIB ● CISCO-Process-MIB ● CISCO-RTTMON-MIB ● CISCO-SMI-MIB ● CISCO-STP-EXTENSIONS-MIB ● CISCO-SYSLOG-MIB ● Cisco-UDLDP-MIB | ● CISCO-TC-MIB ● CICSO-TCP-MIB ● CISCO-VLAN-IFTABLE-Relationship-MIB ● CISCO-VLAN-IFTABLE-MEMBERSHIP-MIB ● CISCO-VTP-MIB ● ENTITY-MIB ● ETHERLIKE-MIB ● IEEE8023-LAG-MIB ● IF-MIB ● INET-Accost-MIB ● OLD-CISCO-CHASSIS-MIB ● Quondam-CISCO-FLASH-MIB ● OLD-CISCO-INTERFACES-MIB ● OLD-CISCO-IP-MIB ● OLD-CISCO-SYS-MIB ● Former-CISCO-TCP-MIB ● OLD-CISCO-TS-MIB ● RFC1213-MIB ● RMON-MIB ● RMON2-MIB ● SNMP-FRAMEWORK-MIB ● SNMP-MPD-MIB ● SNMP-NOTIFICATION-MIB ● SNMP-TARGET-MIB ● SNMPv2-MIB ● TCP-MIB ● UDP-MIB |
Standards | ● IEEE 802.1D Spanning Tree Protocol ● IEEE 802.1p CoS Prioritization ● IEEE 802.1Q VLAN ● IEEE 802.1s ● IEEE 802.1w ● IEEE 802.1X ● IEEE 802.1ab (LLDP without MED*) ● IEEE 802.3ad ● IEEE 802.3ah (100BASE-X unmarried- and multimode fiber but) ● IEEE 802.3x total duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports ● IEEE 802.3 10BASE-T specification ● IEEE 802.3u 100BASE-TX specification ● IEEE 802.3ab 1000BASE-T specification ● IEEE 802.3z 1000BASE-X specification | ● 100BASE-FX (SFP) ● 1000BASE-SX (SFP) ● 1000BASE-Sixty/LH (SFP) ● Remote Monitoring (RMON) I and 2 standards ● SNMPv1, v2c, and v3 |
RFC compliance | ● RFC 768 - UDP ● RFC 783 - TFTP ● RFC 791 - IP ● RFC 792 - ICMP ● RFC 793 - TCP ● RFC 826 - Address Resolution Protocol (ARP) ● RFC 854 - Telnet ● RFC 951 - Bootstrap Protocol (BOOTP) ● RFC 959 - FTP ● RFC 1112 - IP Multicast and IGMP ● RFC 1157 - SNMP v1 ● RFC 1166 - IP addresses ● RFC 1305 - NTP ● RFC 1492 - TACACS+ ● RFC 1493 - Span MIB ● RFC 1542 - BOOTP extensions ● RFC 1643 - Ethernet Interface MIB ● RFC 1757 - RMON | ● RFC 1901 - SNMP v2C ● RFC 1902-1907 - SNMP v2 ● FRC 2068 - HTTP ● RFC 2131 - DHCP ● RFC 2138 - RADIUS ● RFC 2233 - IF MIB ● RFC 2273-2275 - SNMP v3 ● RFC 2474 - Differentiated Services (DiffServ) Precedence ● RFC 2597 - Assured Forwarding ● RFC 2598 - Expedited Forwarding ● RFC 2571 - SNMP Management ● RFC 3046 - DHCP Relay Agent Information Option ● RFC 3376 - IGMP v3 ● RFC 3580 - 802.1X RADIUS |
*Version with MED will be available starting in release IOS12.2.(55)
Table 7. Safety and Compliance
Description | Specification |
Safe certifications | ● UL 60950-1, Second Edition ● Tin can/CSA 22.ii No. 60950-1, 2d Edition ● TUV/GS to EN 60950-1, Second Edition ● CB to IEC 60950-i 2d Edition with all country deviations ● CE Mark ● NOM (through partners and distributors) |
Electromagnetic emissions certifications | ● FCC Part xv Form A ● EN 55022 Class A (CISPR22) ● EN 55024 (CISPR24) ● AS/NZS CISPR22 Class A ● CE ● CNS13438 Form A ● MIC ● GOST ● Communist china EMC Certifications |
Environmental | Reduction of Chancy Substances (ROHS) 5 |
Telco | Common Language Equipment Identifier (CLEI) code |
Warranty | Express lifetime warranty |
Cisco Express Lifetime Hardware Warranty
Cisco Catalyst 2960-S and 2960 Series Switches come with a limited lifetime warranty (Table 8). The warranty for the Catalyst 2960-S has the aforementioned terms as our standard limited lifetime warranty plus the addition of side by side business solar day delivery of replacement hardware where available and 90 days of 8x5 Cisco Technical Assistance (TAC) support. Your formal warranty statement, including the warranty applicable to Cisco software, appears in the Cisco data packet that accompanies your Cisco product. We encourage you to review carefully the warranty statement shipped with your specific production before employ.
Cisco reserves the right to refund the buy price as its exclusive warranty remedy.
For further data on warranty terms, visit http://world wide web.cisco.com/go/warranty.
Table 8. Express Lifetime Warranty Terms
Cisco Limited Lifetime Hardware Warranty | Cisco Enhanced Limited Lifetime Hardware Warranty | |
Device covered | Applies to Cisco Catalyst 2960 Series Switches sold on or later May 1, 2009 | Applies to Cisco Goad 2960-S Series Switches |
Warranty duration | Equally long as the original client owns the product. | As long equally the original terminate user continues to ain or apply the product, provided that: fan and power supply warranty is limited to five (5) years. |
End-of-life policy | In the effect of discontinuance of production manufacture, Cisco warranty support is limited to five (v) years from the announcement of discontinuance. | In the consequence of discontinuance of product manufacture, Cisco warranty support is express to v (5) years from the proclamation of discontinuance. |
Hardware replacement | Cisco or its service center will use commercially reasonable efforts to transport a replacement office within 10 (10) working days after receipt of the RMA request. Actual delivery times may vary depending on customer location. | Cisco or its service center will utilize commercially reasonable efforts to send a Catalyst 2960-S replacement for next business twenty-four hours delivery, where bachelor. Otherwise, a replacement will exist shipped within 10 (10) working days after receipt of the RMA asking. Bodily delivery times may vary depending on customer location. |
Effective engagement | Hardware warranty commences from the appointment of shipment to customer (and in case of resale by a Cisco reseller, not more than 90 [90] days afterwards original shipment by Cisco). | Hardware warranty commences from the date of shipment to customer (and in case of resale by a Cisco reseller, not more ninety [90] days afterward original shipment by Cisco). |
TAC back up | Not included. | Cisco will provide, during customer's local business hours, 8 hours per day, 5 days per week basic configuration, diagnosis, and troubleshooting of device-level problems for upwardly to 90 days from the date of shipment of the originally purchased Goad 2960-Due south product. This support does not include solution or network-level back up across the specific device under consideration. |
Cisco.com Admission | Warranty allows guest access only to Cisco.com | Warranty allows guest admission but to Cisco.com |
Software Update Policy for Cisco Catalyst 2960-Southward and 2960 Series Switches with LAN Lite Software
Customers with Cisco Catalyst LAN Lite software licenses volition exist provided with maintenance updates and bug fixes designed to maintain the compliance of the software with published specifications, release notes, and industry standards compliance as long every bit the original end user continues to own or use the production or for upwards to 1 year from the end-of-sale date for this product, whichever occurs before. Customers with licenses for our premium software images, Enterprise Services or IP Services, crave a service support contract such as Cisco SMARTnet ® Service to download updates.
This policy supersedes any previous warranty or software statement and is subject to change without notice.
Cisco and Partner Services for the Catalyst 2960 Switches
Minimize operating costs and reduce power consumption for the Cisco Catalyst 2960 switch using intelligent, personalized services from Cisco and our partners. Through a discovery process that begins with understanding your business organization objectives, we help you lot integrate the Cisco Goad switch into your compages and incorporate network services onto it. Sharing knowledge and leading practices, nosotros support your success every stride of the way as you deploy, absorb, manage, and scale new technology. Choose from a flexible suite of back up services designed to meet your business needs and assistance yous maintain loftier-quality network operation while controlling operational costs. Table 9 lists the technical services available for the Cisco Catalyst 2960-Due south and 2960 Serial Switches.
Table ix. Technical Services Available for Cisco Goad 2960-S and 2960 Series Switches
Technical Services |
Cisco SMARTnet ® Service ● Around-the-clock, global access to the Cisco TAC ● Unrestricted admission to the extensive Cisco.com knowledge base and tools ● Next-business-day, 8x5x4, 24x7x4, or 24x7x2 accelerate hardware replacement and onsite parts replacement and installation available1 ● Ongoing operating system software updates within the licensed feature set2 ● Proactive diagnostics and existent-fourth dimension alerts on Smart Call Home enabled devices |
Cisco Smart Foundation Service ● Side by side-business-day advance hardware replacement as available ● Admission to SMB TAC during business organisation hours (admission levels vary past region) ● Access to Cisco.com SMB cognition base ● Online technical resources through the Smart Foundation Portal ● Operating system software problems fixes and patches |
Cisco Smart Intendance Service ● Network-level coverage for the needs of modest and medium-sized businesses ● Proactive wellness checks and periodic assessments of Cisco network foundation, phonation, and security technologies ● Technical support for eligible Cisco hardware and software through Smart Care Portal ● Cisco operating system and application software updates and upgrades2 ● Next-business-twenty-four hour period advance hardware replacement as bachelor, 24x7x4 option available one |
Cisco SP Base Service ● Around-the-clock, global admission to the Cisco TAC ● Registered access to Cisco.com ● Side by side concern day, 8x5x4, 24x7x4, and 24x7x2 accelerate hardware replacement. Render to factory option available 1 ● Ongoing operating organisation software updates2 |
Cisco Focused Technical Support Services 3 levels of premium, high-touch services are available: ● Cisco High-Touch Operations Management Service ● Cisco High-Touch Technical Back up Service ● Cisco High-Bear upon Engineering Service Valid Cisco SMARTnet or SP Base of operations contracts are required on all network equipment. |
Footnotes:
one. Advance hardware replacement is available in various service-level combinations. For example, 8x5xNBD indicates that shipment will be initiated during the standard 8-hour business day, 5 days a week (the generally accepted business organization days within the relevant region), with next-business-solar day (NBD) delivery. Where NBD is not available, same day shipping is provided. Restrictions apply; please review the appropriate service descriptions for details.
2. Cisco operating system updates include the following: maintenance releases, minor updates, and major updates within the licensed feature set up.
Ordering Information
Table 10 has ordering data for the Cisco Catalyst 2960-S and 2960 Series Switches with LAN Low-cal Software.
Tabular array 10. Ordering Information for Cisco Catalyst 2960 Serial Switches with LAN Lite Software
Part Numbers | Description | |
Cisco Catalyst 2960S-48TS-Due south | ● 48 Ethernet ten/100/k ● 2 One Gigabit Ethernet SFP uplink ports ● LAN Calorie-free software | |
Cisco Goad 2960S-24TS-South | ● 24 Ethernet ten/100/1000 ● 2 I Gigabit Ethernet SFP uplink ports ● LAN Lite software | |
WS-C2960-8TC-Due south | ● 8 Ethernet 10/100 ports and ane dual-purpose uplink (dual-purpose uplink port has 1 10/100/thousand Ethernet port and i SFP-based Gigabit Ethernet port, ane port active) ● LAN Lite software ● Compact size with no fan; mounting magnet included | |
WS-C2960-24-South | ● 24 Ethernet 10/100 ports ● LAN Calorie-free software | |
WS-C2960-24TC-S | ● 24 Ethernet 10/100 ports and 2 dual-purpose uplinks (each dual-purpose uplink port has 1 10/100/1000 Ethernet port and 1 SFP-based Gigabit Ethernet port, 1 port agile) ● LAN Light software | |
WS-2960-24PC-S | ● 24 Ethernet 10/100 ports and 2 dual-purpose uplinks (each dual-purpose uplink port has 1 10/100/thou Ethernet port and 1 SFP-based Gigabit Ethernet port, 1 port active) ● LAN Light software ● 24 PoE ports | |
WS-2960-24LC-S | ● 24 Ethernet ten/100 ports and ii dual-purpose uplinks (each dual-purpose uplink port has 1 10/100/one thousand Ethernet port and 1 SFP-based Gigabit Ethernet port, 1 port active) ] ● LAN Calorie-free software ● 8 PoE ports | |
WS-C2960-48TT-S | ● 48 Ethernet 10/100 ports and 2 10/100/thou TX uplinks ● LAN Low-cal software | |
WS-C2960-48TC-Due south | ● 48 Ethernet 10/100 ports and two dual-purpose uplinks (each dual-purpose uplink port has 1 10/100/1000 Ethernet port and one SFP-based Gigabit Ethernet port, ane port agile) ● LAN Lite software | |
WS-2960-48PST-S | ● 48 Ethernet 10/100 ports and two x/100/m uplinks and 2 SFP uplinks ● LAN Calorie-free software ● 48 PoE ports | |
Spare Rack-Mount Kits for the Cisco Goad 2960 Serial Switches with LAN Light Software | ||
RCKMNT-1RU= | ● Spare rack-mount kit for the Cisco Catalyst 2960 and 2960-S Serial | |
RCKMNT-REC-1RU= | ● 1 RU recessed rack-mountain kit for the Cisco Goad 2960 and 2960-S Serial | |
Ability Cords | ||
CAB-16AWG-AC | Air conditioning Power cord, 16AWG | |
CAB-ACE | AC Power Cord (Europe), C13, CEE 7, i.5M | |
CAB-L620P-C13-United states of america | Power Cord, 250VAC, 15A, NEMA L6-20 to C13, U.s.a. | |
CAB-ACI | AC Ability String (Italy), C13, CEI 23-16, 2.5m | |
CAB-ACU | Air conditioning Power String (UK), C13, BS 1363, 2.5m | |
CAB-ACA | Air-conditioning Power Cord (Prc/Australia), C13, Every bit 3112, 2.5m | |
CAB-ACS | AC Ability String (Switzerland), C13, IEC 60884-1, 2.5m | |
CAB-ACR | AC Power Cord (Argentine republic), C13, EL 219 (IRAM 2073), 2.5m | |
CAB-ACC | CORD,PWR,Communist china,10A,IEC 320,C13(APN=CS-PWR-CH) | |
CAB-3P-JPN | CABASY,POWER CORD,Nippon 3P, PSE, 12A @125VAC | |
CAB-L620P-C13-JPN | Ability Cord, 250VAC, 15A, NEMA L6-twenty to C13, Nippon | |
CAB-IND-10A | Ability cable for India | |
CAB-AC15A-90L-US | 15A AC Pwr Cord, left-angle (U.s.) | |
CAB-ACE-RA | Power String Europe, Right Angle | |
CAB-ACI-RA | Power Cord-Italian, Right Angle | |
CAB-ACU-RA | Power Cord UK, Right Angle | |
CAB-ACC-RA | Power Cord China, Correct Angle | |
CAB-ACA-RA | Power Cord, Australian, Right Bending | |
CAB-ACS-RA | Power Cord for Switzerland, Right Angle | |
CAB-ACR-RA | Power Cord, Argentina, Right Angle | |
CAB-JPN-RA | Power Cord, Japan, Correct Angle | |
Optical Transceivers for the Cisco Catalyst 2960 Series Switches with LAN Calorie-free Software | ||
GLC-LH-SM= | 1000BASE-LX/LH SFP transceiver module for MMF and SMF, 1300-nm wavelength | |
GLC-SX-MM= | 1000BASE-SX SFP transceiver module for MMF, 850-nm wavelength | |
GLC-T= | 1000BASE-T SFP transceiver module for Category 5 copper wire | |
GLC-GE-100FX= | 100BASE-FX SFP module for Gigabit Ethernet ports, 1310-nm wavelength, 2 km over MMF | |
GLC-Atomic number 26-100FX= | 100BASE-FX SFP module for 100-Mb ports, 1310-nm wavelength, ii km over MMF | |
CAB-SM-LCSC-1M | 1m fiber single-mode LC-to-SC connectors | |
CAB-SM-LCSC-5M | 5m cobweb single-mode LC-to-SC connectors | |
For latest information on transceivers, please go to: http://world wide web.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html.
For more information virtually Cisco products, contact:
● Us and Canada: (cost gratis) 800 553-NETS (6387)
● Europe: 32 2 778 4242
● Commonwealth of australia: 612 9935 4107
● Other: 408 526-7209
● World Wide Web URL: http://www.cisco.com
Source: https://www.cisco.com/c/en/us/products/collateral/switches/catalyst-2960-series-switches/product_data_sheet0900aecd806b0bd8.html
0 Response to "Cisco Wsc296024tcl Catalyst 2960 24port 10100 Managed Switch Business Reviews"